Whistle--Signals
The following standard signals shall be adopted and used for the type of operation listed. If a standard signal is not listed to cover an unusual or new situation, a new signal may be adopted and used for that specific situation.
HIGH-LEAD LOGGING WHISTLE SIGNALS 1 short..........................................Stop all lines 3 short--3 short........................ Ahead slow on mainline 3 short...................................... Ahead on mainline 2 short...................................... Ahead on haulback 2 short--2 short........................ Ahead slow on haulback 3 short--1 short............................ Ahead on strawline 3 short--1 short--3 short.............. Ahead slow on strawline 4 short......................................... Slack mainline 2 short--4 short................................ Slack haulback 3 short--1 short--4 short...................... Slack strawline 3 short--2 short.................................... Tight line 3 short........................... When rigging is in:strawline back on haulback 3 short plus "X" number of shorts.When rigging is in: Indicates number of sections of strawline back on rigging 3 short--1 short--2 short............ Strawline back on rigging 1 short.................... When rigging is in: Chaser inspect and repair rigging 2 short.................... When rigging is in: No chokers back 2 short--1 short plus "X" number of shorts..Number chokers back 2 short--4 short..............When rigging in: Slack haulback-- hold all lines until 2 short blown 3 medium................................................ Hooker 3 medium--4 short.......................... Hooker and his crew 5 long................................................. Climber 4 long................................................. Foreman 1 long--1 short............................. Start or stop work 7 long--2 short. Man injured, call transportation and stretcher 1 long--1 short repeated.................................. Fire GRABINSKI SYSTEM 2 short--1 short.................................. Slack mainline and haulback together 2 long............................................ Take off or put on rider block SLACK LINE WHISTLE SIGNALS 2 short--2 short--2 short.........................First cable up when road has been changed and tail hold made fast 2 short--2 short--2 short......................... Drop skyline 1 short........................................... Stop any moving line 1 long............................................ When logging, slack skyline 2 short........................................... Ahead on skyline 1 long--2 short................................... Ahead easy on skyline 3 short........................................... Ahead on skidding line, holding haulback 3 short--3 short..................................Ahead easy on skidding line with slack haulback 4 short........................................... Slack skidding line 2 short--2 short--repeated once................... Ahead easy on haulback with slack skidding line 2 short--2 short.................................. Ahead on haulback 2 short--2 short--4 short......................... Slack haulback 2 short--pause--3 short........................... Pick up skyline and skid 2 short--pause--2 short--2 short.................. Pick up skyline and skid 3 short--1 short..................................When carriage is in: strawline back on haulback 3 short--1 short--2 short.........................When carriage is in: strawline back on carriage 3 short--1 short.................................. When strawline is out: ahead on strawline 3 short--2 short.................................. Tight line 3 short--1 short--4 short......................... Slack strawline 3 short--1 short--3 short......................... Pull easy on strawline 2 long............................................ Ahead on transfer 2 long--4 short................................... Slack transfer 2 long--2 short--2 short.......................... When carriage is in: transfer back on carriage 1 long--1 short................................... When carriage is in: number of coils 2 short--2 short--1 or more short spaced.......... When carriage is in number of chokers 1 short...........................................When carriage is in: inspect rigging, repair, and send back 2 short--2 short--4 short......................... When carriage is in: slack haulback and hold all lines until 1 short is blown; then send back 3 short--3 short.................................. When carriage is in: send back powder 5 medium.......................................... Tail rigger 5 medium--4 short................................. Tail rigger and his crew 3 medium.......................................... Head hooker 3 medium--4 short................................. Second hooker and his crew 5 long............................................ Climber 4 long............................................ Foreman 1 long--1 short................................... Start or stop work 7 long--2 short...................................Man injured, call transportation and stretcher 1 long--1 short repeated.......................... Fire SKIDDER WHISTLE SIGNALS 1 short........................................... Stops moving carriage. Stops or goes ahead on slack puller as case may be, if carriage is stopped 2 short........................................... Go ahead on skidding line holding carriage 1 short--2 short.................................. Pick up skidding line, easy 2 short--1 short.................................. Shake up carriage to clear choker 2 short--2 short.................................. Ahead on receding line 3 short........................................... Ahead on carriage, holding at present level, using interlock 2 short--3 short--3 short......................... Ahead easy on skidding line 2 short--2 short--2 short......................... Slack skyline, cable down 2 short--2 short--2 short--1 short................ Pick up skyline, cable up 2 short--2 short--4 short......................... Slack receding line 2 short--4 short.................................. Slack skidding line 2 short--2 short--1 short......................... Tighten all lines 1 short--4 short.................................. Slack off slack puller 1 short--2 short.................................. Pick up slack puller when slack 2 short--2 short--1 short......................... When carriage is in: to be used for number of chokers wanted 2 short--2 short--1 long.......................... To be used for bull choker 1 short........................................... When carriage is in: inspect butt rigging 2 short--4 short--1 short......................... For each additional 10 feet of long line 1 long--1 short................................... Number of coils of strawline wanted 5 medium.......................................... Tail or second rigger 5 medium--4 short................................. Tail or second rigger and his crew 2 medium.......................................... Skidder head rigger 3 medium--4 short................................. Hooker and his crew 2 long............................................ Ahead on transfer 2 long--4 short................................... Slack transfer 1 short--3 short.................................. Ahead on carriage with slack puller line 1 long............................................ Ahead on strawline 1 long--4 short................................... Slack strawline 1 long--3 short................................... Ahead easy on strawline 5 long............................................ Climber 4 long............................................ Foreman 1 long--1 short................................... Start or stop work 7 long--2 short................................... Man injured, call transportation and stretcher 1 long--1 short repeated.......................... Fire RUNNING SKYLINE WHISTLE SIGNALS 1 short........................................... STOP or DROP dropline 2 short........................................... Go ahead on dropline 1 short--2 short.................................. Go ahead on dropline EASY 2 short--2 short.................................. Ahead on haulback 3 short-3 short................................... Ahead on mainline 3 short........................................... Ahead on mainline EASY 2 short--2 short--2 short......................... Slack carriage 2 short--2 short--1 short......................... Tight line 1 long............................................ Ahead on strawline 1 long--4 short................................... Slack strawline 1 long--3 short................................... Ahead EASY on strawline 3 short........................................... When carriage in: strawline back on haulback 1 long--1 short................................... START or STOP WORK 4 long............................................ FOREMAN 2 short--2 short--plus "X" shorts................. When carriage is in, number of chokers WANTED 1 long--1 short--plus "X" shorts.................. Number of strawline sections WANTED
Go Back to Article 17 Table of Contents