|  Return to index  New query  | 
(a) When a mobile crane is mounted on a barge, the rated load of the crane shall not exceed the capacity specified by the certified agent.
(b) Load ratings shall be reduced to stay within the limits for list of the barge with a crane mounted on it and a revised load rating chart shall be provided.
(c) Mobile cranes on barges shall be secured to the barge. When stability of barge is not a factor, and control barriers are provided, limited travel may be authorized.
(d) The width of barge hulls supporting mobile cranes equipped with pile driver or extractor leads shall be not less than 45 percent of the height of the lead above water.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. Amendment filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 39).
Go Back to Article 93 Table of Contents