This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Chapter 4. Division of Industrial Safety
Subchapter 7. General Industry Safety Orders
Group 16. Control of Hazardous Substances
Article 109. Hazardous Substances and Processes

Return to index
New query


§Appendix A to Section 5189 - List of Acutely Hazardous Chemicals, Toxics and Reactives (Mandatory)


This Appendix contains a listing of substances which present a potential for a catastrophic event at or above the threshold quantity (TQ).
CHEMICAL name
CAS *
TQ **
Acetaldehyde
 
75-07-0
2500
Acrolein (2-Propenal)
 
107-02-8
150
Acrylyl Chloride
 
814-68-6
250
Allyl Chloride
 
107-05-1
1000
Allylamine
 
107-11-9
1000
Alkylaluminums
 
Varies
5000
Ammonia, Anhydrous
 
7664-41-7
10000
Ammonia solutions (> 44% ammonia by weight
 
7664-41-7
15000
Ammonium Perchlorate
 
7790-98-9
7500
Ammonium Permanganate
 
7787-36-2
7500
Arsine (also called Arsenic Hydride)
 
7784-42-1
100
Bis(Chloromethyl) Ether
 
542-88-1
100
Boron Trichloride
 
10294-34-5
2500
Boron Trifluoride
 
7637-07-2
250
Bromine
 
7726-95-6
1500
Bromine Chloride
 
13863-41-7
1500
Bromine Pentafluoride
 
7789-30-2
2500
Bromine Trifluoride
 
7787-71-5
15000
3-Bromopropyne (also called Propargyl Bromide)
 
106-96-7
100
Butyl Hydroperoxide (Tertiary)
 
75-91-2
5000
Butyl Perbenzoate (Tertiary)
 
614-45-9
7500
Carbonyl Chloride (see Phosgene)
 
75-44-5
100
Carbonyl Fluoride
 
353-50-4
2500
Carbonyl Nitrate (concentration > 12.6% nitrogen)
 
9004-70-0
2500
Chlorine
 
7782-50-5
1500
Chlorine Dioxide
 
10049-04-4
1000
Chlorine Pentrafluoride
 
13637-63-3
1000
Chlorine Trifluoride
 
7790-91-2
1000
Chlorodiethylaluminum (also called Diethylaluminum Chloride)
 
96-10-6
5000
1-Chloro-2,4-Dinitrobenzene
 
97-00-7
5000
Chloromethyl Methyl Ether
 
107-30-2
500
Chloropicrin
 
76-06-2
500
Chloropicrin and Methyl Bromide mixture
 
None
1500
Chloropicrin and Methyl Chloride mixture
 
None
1500
Cumene Hydroperoxide
 
80-15-9
5000
Cyanogen
 
460-19-5
2500
Cyanogen Chloride
 
506-77-4
500
Cyanuric Fluoride
 
675-14-9
100
Diacetyl Peroxide (Concentration > 70%)
 
110-22-5
5000
Diazomethane
 
334-88-3
500
Dibenzoyl Peroxide
 
94-36-0
7500
Diborane
 
19287-45-7
100
Dibutyl Peroxide (Tertiary)
 
110-05-4
5000
Dichloro Acetylene
 
7572-29-4
250
Dichlorosilane
 
4109-96-0
2500
Diethylzinc
 
557-20-0
10000
Diisopropyl Peroxydicarbonate
 
105-64-6
7500
Dilaluroyl Peroxide
 
105-74-8
7500
Dimethyldichlorosilane
 
75-78-5
1000
Dimethylhydrazine, 1,1-
 
57-14-7
1000
Dimethylamine, Anhydrous
 
124-40-3
2500
2,4-Dinitroaniline
 
97-02-9
5000
Ethyl Methyl Ketone Peroxide (also
Methyl Ethyl Ketone Peroxide;
concentration > 60%)
 
1338-23-4
5000
Ethyl Nitrite
 
109-95-5
5000
Ethylamine
 
75-04-7
7500
Ethylene Fluorohydrin
 
371-62-0
100
Ethylene Oxide
 
75-21-8
5000
Ethyleneimine
 
151-56-4
1000
Fluorine
 
7782-41-4
1000
Formaldehyde (Formalin)
 
50-00-0
1000
Furan
 
110-00-9
500
Hexafluoroacetone
 
684-16-2
5000
Hydrochloric Acid, Anhydrous
 
7647-01-0
500
Hydrofluoric Acid, Anhydrous
 
7664-39-3
1000
Hydrogen Bromide
 
10035-10-6
5000
Hydrogen Chloride
 
7647-01-0
5000
Hydrogen Cyanide, Anhydrous
 
74-90-8
1000
Hydrogen Fluoride
 
7664-39-3
1000
Hydrogen Peroxide (52% by weight
or greater
 
7722-84-1
7500
Hydrogen Selenide
 
7783-07-5
150
Hydrogen Sulfide
 
7783-06-4
1500
Hydroxylamine
 
7803-49-8
2500
Iron, Pentacarbonyl
 
13463-40-6
250
Isopropylamine
 
75-31-0
5000
Ketene
 
463-51-4
100
Methacrylaldehyde
 
78-85-3
1000
Methacryloyl Chloride
 
920-46-7
150
Methacryloyloxyethyl Isocyanate
 
30674-80-7
100
Methyl Acrylonitrile
 
126-98-7
250
Methylamine, Anhydrous
 
74-89-5
1000
Methyl Bromide
 
74-83-9
2500
Methyl Chloride
 
74-87-3
15000
Methyl Chloroformate
 
79-22-1
500
Methyl Ethyl Ketone Peroxide
(concentration > 60%)
 
1338-23-4
5000
Methyl Fluoroacetate
 
453-18-9
100
Methyl Fluorosulfate
 
421-20-5
100
Methyl Hydrazine
 
60-34-4
100
Methyl Iodide
 
74-88-4
7500
Methyl Isocyanate
 
624-83-9
250
Methyl Mercaptan
 
74-93-1
5000
Methyl Vinyl Ketone
 
78-94-4
100
Methyltrichlorosilane
 
75-79-6
500
Nickel Carbonly (Nickel
Tetracarbonyl)
 
13463-39-3
150
Nitric Acid (94.5% by weight or
greater)
 
7697-37-2
500
Nitric Oxide
 
10102-43-9
250
Nitroaniline (para Nitroaniline
 
100-01-6
5000
Nitromethane
 
75-52-5
2500
Nitrogen Dioxide
 
10102-44-0
250
Nitrogen Oxides (NO; NO 2; N204;
N203)
 
10102-44-0
250
Nitrogen Tetroxide (also called Nitro
gen Peroxide)
 
10544-72-6
250
Nitrogen Trifluoride
 
7783-54-2
5000
Nitrogen Trioxide
 
10544-73-7
250
Oleum (65% to 80% by weight; also
called Fuming Sulfuric Acid)
 
8014-95-7
1000
Osmium Tetroxide
 
20816-12-0
100
Oxygen Difluoride (Fluorine Monox-
ide)
 
7783-41-7
100
Ozone
 
10028-15-6
100
Pentaborane
 
19624-22-7
100
Peracetic Acid (concentration > 60%
Acetic Acid; also called
Peroxyacetic Acid)
 
79-21-0
1000
Perchloric Acid (concentration > 60%
by weight)
 
7601-90-3
5000
Perchloromethyl Mercaptan
 
594-42-3
150
Perchloryl Fluoride
 
7616-94-6
5000
Peroxyacetic Acid (concentration >
60% Acetic Acid; also called
Peracetic Acid)
 
79-21-0
1000
Phosgene (also called Carbonyl
Chloride)
 
75-44-5
100
Phosphine (Hydrogen Phosphide)
 
7803-51-2
100
Phosphorus Oxychloride (also called
Phosphoryl Chloride)
 
10025-87-3
1000
Phosphorus Trichloride
 
7719-12-2
1000
Phosphoryl Chloride (also called
Phosphorus Oxychloride)
 
10025-87-3
1000
Propargyl Bromide
 
106-96-7
100
Propyl Nitrate
 
627-3-4
2500
Sarin
 
107-44-8
100
Selenium Hexafluoride
 
7783-79-1
1000
Stibine (Antimony Hydride)
 
7803-52-3
500
Sulfur Dioxide (liquid)
 
7446-09-5
1000
Sulfur Pentafluoride
 
5714-22-7
250
Sulfur Tetrafluoride
 
7783-60-0
250
Sulfur Trioxide (also called Sulfuric
Anhydride)
 
7446-11-9
1000
Sulfuric Anhydride (also called Sulfur
Trioxide)
 
7446-11-9
1000
Tellurium Hexafluoride
 
7783-80-4
250
Tetrafluoroethylene
 
116-14-3
5000
Tetrafluorohydrazine
 
10036-47-2
5000
Tetramethyl Lead
 
75-74-1
1000
Thionyl Chloride
 
7719-09-7
250
Trichloro (chloromethyl) Silane
 
1558-25-4
100
Trichloro (dichlorophenyl) Silane
 
27137-85-5
2500
Trichlorosilane
 
10025-78-2
5000
Trifluorochloroethylene
 
79-38-9
10000
Trimethyoxysilane
 
2487-90-3
1500
*Chemical Abstract Service Number.
**Threshold Quantity in Pounds (Amount necessary to be covered by this standard).
Note: Authority cited: Section 142.3, Labor Code. Reference: Sections 142.3 and 7856, Labor Code.