Authority for Standard | Date of Issue | Title or Description of Standard | See Section |
---|---|---|---|
ACMA: | |||
420.03 | 1963 | Practice for Helical and Herringbone Gear Speed Reducers | 3091(n)(4) |
430.03 | 1963 | Practice for Speed Reducers and Increasers Employing Spiral Bevel Gearing | 3091(n)(4) |
440.03 | 1959 | Practice for Single and Double Reduction Cylindrical-Worm and Helical-Worm Speed Reducers | 3091(n)(4) |
441.03 | 1963 | Practice for Single and Double Reduction-Cylindrical, Double-Enveloping Worm and Helical-Worm Speed Reducers | 3091(n)(4) |
460.04 | 1965 | Practice for Gearmotors | 3091(n)(4) |
480.03 | 1965 | Practice for Helical, Herringbone and Spur Gear Shaft Mounted Speed Reducers | 3091(n)(4) |
ASTM: | |||
A36 | 1968 | Specification for Scructural Steel | M101(a)(1) |
A235 | 1967 | Specification for Carbon Steel Forgings for General Industrial Use | 3101(a)(1) |
3107(b)(3) | |||
3107(b)(5) | |||
A283 | 1967 | Specification for Low and Intermediate Tensile Strength Carbon Steel Plate of Structural Quality | 3101(a)(1) |
A307 | 1967 | Specification for Low Carbon Steel Externally and Internally Threaded Standard Fasteners | 3101(a)(1) |
3109(b)(2) | |||
3111(c)(1) | |||
3111(c)(2) | |||
A502 | 1965 | Specifications for Steel Structural Rivets | 3101(a)(1) |
3109(b)(3) | |||
3111(c)(2) | |||
D2270 | 1964 | Viscosity Index from Kinematic Viscosity | 3108(e) |
SAE: | |||
100-R2 | 1967 | High Pressure Steel Wire Reinforced Rubber Covered Hydraulic Hose | 3068(a)(3) |
Federal | |||
Specification | |||
DD-G-451c | 1968 | Glass, Plate, Sheet, Figured (Float, Flat, for Glazing, Corrugated, Mirrors, and Other Uses) | 3034(b) (5)(E) |
USAS: | |||
A2.5 | 1963 | Method of Test For Surface Burning Characteristics of Building Materials | 3101(a)(3) |
ASTM 84 | |||
NFPA 255 | 1961 | ||
A17.1 and | 1965 | Safety Code for Elevators, Dumb waiters, Escalators, and Moving Walks | 3000(d) |
Supplements | 1967 | 3108(f)(1) | |
.1a | |||
.1b | 1968 | ||
.1c | 1969 | ||
B2.1 | 1968 | Pipe Threads (Except Dry Seal) | 3102(g)(5) |
B29.1 | 1963 | Transmission Roller Chains and Sprocket Teeth | 3091(n)(5) |
B29.2 | 1957 | Inverted Tooth (Silent) Chains and Sprocket Teeth | 3091(n)(5) |
B31.1.0 | 1967 | Power Piping | 3102(g)(2) |
B55.1 | 1961 | Specifications for Multiple V-Belt Drives | 3091(n)(6) |
G50.1 | 1967 | Specifications for Mild to Medium Strength Carbon Steel Castings for General Application | 3101(a)(1) |
ASTM A27 | 1965 | 3107(b)(3) | |
Z11.5 | 1966 | Method of Test for Pour Point | 3108(e) |
ASTM D97 | 1966 | ||
Z97.1 | 1966 | Performance, Specifications and Method of Test for Transparent Safety Glazing Materials Used in Buildings | 3034(a)(7) |
3034(b)(5) | |||
3089(d)(2) | |||
3091(k)(1) | |||
3091(l) |
Go Back to Article 5 Table of Contents